Primary voltage:120Vac/60Hz OR 240Vac/50Hz (Please state the primary voltage suitable for your country)
Secondary voltages:
Core size:EI75/35
wire leads length: 400mm
Weight : 1,3 Kgr
Dimensions: 66mmx95x75mm Mounting: horizontal placement .
TECHNICAL FEATURES:
Primary voltage: 240Vac/50Hz OR 120Vac/60Hz (Please state the primary voltage suitable for your country)
The transformer can be customized to you specs within the VA rating of the core
360Vac /450mA
75-0-75Vac/150mA
6.3Vac/4A
6.3Vac/2A
12Vac/1.2A CT
Core size:EI120/60
Weight : 6.2Kgr
Dimensions: 120mmx105x140mm
Mounting: Vertical
Secondary voltages: 0-235-250-265-280-295-315-330Vac /160mA
6.3Vac/4A CT
Core size:EI84/50
Weight :2.3Kgr
Dimensions: 82mmx75mmx87mm
Dynaco ST70 Power Transformer Upgrade.
This transformer is suitable for upgrading dynaco ST70 amplifier or building a project based on ST70 topology. Please note that the transformer is not a drop in replacement.
The transformer is built in a bigger core to ensure cooler running and improved voltage regulation due to the lower winding resistance.
Secondary voltages: 360V-0-55V-360V /300mA
6.3Vac/5A
5Vac/4A
Weight :6 Kgr
Dimensions: 120mmx100x100mm
Mounting Bolt pattern :80mmx100mm, M5 screw hole
Mounting: drop through chassis
The transformer can be used in tube amplifier projects to unload the main power transformer or heaters chain. In preamplifiers ,the sonic benefits when powering the heaters from a separate transformer and not the one that supplies the high voltage , are extended .
primary voltage: 230/240Vac/50Hz OR120Vac/60Hz (Please state the primary voltage suitable for your country) The secondary voltages can be customized within the VA rating of the core
secondary Voltages:
6.3Vac/3A
6.3Vac/1.2A CT
Core size:EI75/40
weight: 1.5 per transformer
dimensions: 78mx93mmx63mm
Winding Wire: Double coated Grade 2 enamelled copper wire made in Europe
core material: high quality , low loss silicon steel made in Europe
Primary voltage: 240Vac/50Hz OR 120Vac/60Hz
(Please state the primary voltage suitable for your country)
620Vac /300mA
350Vac/50mA
100Vac/50mA
15Vac/200mA
12Vac/5.2A
Primary voltage:230/240Vac/50Hz OR 120Vac/60Hz (Please state the primary voltage suitable for your country)
Secondary voltages: 1000-900-800-0-800-900-1000Vac /160mA
Core size:EI120/50
Weight : 4.92Kgr
Dimensions: 120mmx100x90mm Mounting: drop through chassis placement.
Tube amplifier projects and related circuits use high voltage and contact with high voltages can cause serious injury or death.
If you are not experienced with high voltage safety and working with high voltage, this is not the project for you and you act at your own risk and responsibility.
Dynaco ST35 Power Transformer Upgrade.
This transformer is suitable for upgrading dynaco ST35 amplifier or building a project based on ST35 topology. Please note that the transformer is not a drop in replacement(Please see the dimensions in the photos).
Secondary voltages: 2x330Vac /180mA DC ct 6.3Vac/2.5A 6.3Vac/2.5A
Wire leads length: 400mm
Weight : 2.36 Kgr
Dimensions: 75mmx121x84mm
Mounting: horizontal placement
Secondary voltages: 2x330Vac /20mA ct 10.9V/1.5A ( on request the transformer can be built with different fillament voltage)
Core size:EI75/25 wire leads length: 400mm
Weight : 1,09 Kgr
Dimensions: 66mmx81x75mm
Mounting: horizontal placement .
Tube amplifier projects and related circuits use high voltage and contact with high voltages can cause serious injury or death. If you are not experienced with high voltage safety and working with high voltage, this is not the project for you and you act at your own risk and responsibility.
Primary voltage: 230Vac/50Hz OR120Vac/60Hz (Please state the primary voltage suitable for your country)
The secondary voltages can be customized within the VA rating of the core
Secondary Voltages:
250Vac/20mA ,
0-9-14V/1.6A
Core size:EI60/30
Weight: 720gr per transformer
Dimensions: 62mx51.5mmx55mm (86mm foot distance)
Footprint hole: 5x6mm
Core material: high quality , low loss silicon steel made in Europe
Warning: Tube amplifier projects and related circuits uses high voltage and contact with high voltages can cause serious injury or death. If you are not experienced with high voltage safety and working with high voltage, this is not the project for you and you act at your own risk and responsibility.