TECHNICAL FEATURES:
Primary Impedance: 16K (Anode to Anode) or 21K (depending on the secondary load)
Secondary Impedance: 6 Ω or 8Ω
Primary Inductance Lp=350H @17Vrms/50hz
Leakage inductance : 150mH Primary
Dc resistance:180 Ohm
Max Dc current per tube :350mA (Anode to CT)
Maximum output power : 100W
Frequency Response: 7.2Hz-62Khz -3bB
core material: high quality grain oriented silicon steel (19000Gauss) annealed, made in Europe
core size : EI120 /70
Lamination thickness :0.35mm
dimensions :120mmx105mmx120mm
weight :6.6Kgr per transformer
Winding method :layer wound with insulation insertion between every layer.
Winding Wire: Double coated Grade 2 enamelled copper wire made in Europe, wound in Precision Multi section winding, for reduced leakage inductance, low parasitic capacitance and high dielectric strength.
Mounting: vertical or horizontal placement