TECHNICAL FEATURES:
Primary Impedance: 8K (Anode to Anode)
Secondary Impedance: 8Ω
Primary Inductance Lp=350H @230Vrms/50hz
Leakage inductance : 5.6mH/1Khz
Primary Dc resistance:137 Ohm
Max Dc current per tube :350mA (Anode to CT)
Maximum output power : 100W
Frequency Response: 4Hz-77Khz -3bB (test condition 2x6L6 triode mode, 1.5W output/8R)
core material: high quality silicon steel, made in Europe
core size : EI120 /60
Lamination thickness :0.35mm
dimensions :120mmx105mmx120mm
weight :5.6Kgr per transformer
Winding method :layer wound with insulation insertion between every layer.
Winding Wire: Double coated Grade 2 enamelled copper wire made in Europe, wound in Precision Multi section winding, for reduced leakage inductance, low parasitic capacitance and high dielectric strength.
Mounting: vertical