TECHNICAL FEATURES:
Primary Impedance: 6k6 (Anode to Anode)
Secondary Impedance: 4/8 Ω (all secondaries are independed and the user can wire the transformer's secondary to have 4Ohm or 8Ohm load match ,without wasting any part of secondary , according to the schematic provided with the transformers)
ultralinear taps : 42%
Primary Inductance Lp=114H @17Vrms/50hz
Leakage inductance : 12mH
Primary Dc resistance: 173 Ohm
Max Dc current per tube :240mA (Anode to CT)
Maximum output power : 60W
Frequency Response: 10Hz-74Khz -3bB at 30W output power core material: high quality silicon steel made in Europe
Core size : EI96 /60
Lamination thickness :0.35mm
Dimensions :129mmx97mmx86mm
Weight :3.42Kgr per transformer
Winding method :layer wound with insulation insertion between every layer.
Winding Wire: Double coated Grade 2 enamelled copper wire made in Europe Wound in Precision Multi section winding, for reduced leakage inductance, low parasitic capacitance and high dielectric strength.
Mounting: horizontal placement